128 research outputs found

    Beyond Einstein: Exploring the Extreme Universe

    Get PDF
    This paper will give an overview of the NASA Universe Division Beyond Einstein program. The Beyond Einstein program consists of a series of exploratory missions to investigate some of the most important and pressing problems in modern-day astrophysics - including searches for Dark Energy and studies of the earliest times in the universe, during the inflationary period after the Big Bang. A variety of new technologies are being developed both in the science instrumentation these missions will carry and in the spacecraft that will carry those instruments

    Simulated Performance of 3-DTI Gamma-Ray Telescope Concepts

    Get PDF
    We present Monte Carlo simulations of two astronomical gamma-ray telescope concepts based on the ThreeDimensional Track Imager (3- DTI) detector. The 3-DTI consists of a time projection chamber with two-dimensional, crossedstrip micro-well detector readout. The full three- dimensional reconstruction of charged-particle tracks in the gas volume is obtained from transient digitizers, which record the time signature of the charge collected in the wells of each strip. Such detectors hold great promise for advanced Compton telescope (ACT) and advanced pair telescope (APT) concepts due to the very precise measurement of charged particle momenta that is possible (Compton recoil electrons and electron-positron pairs, respectively). We have investigated the performance of baseline ACT and APT designs based on the 3-DTI detector using simulation tools based on GEANT3 and GEANT4, respectively. We present the expected imaging, spectroscopy, polarimetry, and background performance of each design

    Medium-Energy Gamma-Ray Astrophysics with the 3-DTI Gamma-Ray Telescope

    Get PDF
    Gamma-ray observations in the medium energy range (0.50-50.0 MeV) are central to unfolding many outstanding questions in astrophysics. The challenges of medium-energy gamma-ray observations, however, are the low photon statistics and large backgrounds. We review these questions, address the telescope technology requirements, and describe our development of the 3-Dimensional Track Imaging (3-DTI) Compton telescope and its performance for a new mediumenergy gamma-ray mission. The 3-DTI is a large-volume time projection chamber (TPC) with a 2-dimensional gas micro-well detector (MWD) readout

    Physiological traits of Penicillium glabrum strain LCP 08.5568, a filamentous fungus isolated from bottled aromatised mineral water

    No full text
    International audiencePenicillium glabrum is an ubiquitous fungus distributed world wide. This fungus is a frequent contaminant in the food manufacturing industry. Environmental factors such as temperature, water activity and pH have a great influence on fungal development. In this study, a strain of P. glabrum referenced to as LCP 08.5568, has been isolated from a bottle of aromatised mineral water. The effects of temperature, aw and pH on radial growth rate were assessed on Czapeck Yeast Agar (CYA) medium. Models derived from the cardinal model with inflection (Rosso et al., 1993 An unexpected correlation between cardinal temperatures of microbial growth highlighted by a new model. J Theor. Bio. 162, 447-463) were used to fit the experimental data and determine for each factor, the cardinal parameters (minimum, optimum and maximum). Precise characterisation of the growth conditions for such a fungal contaminant, has an evident interest to understand and to prevent spoilage of food products

    The Burst Alert Telescope (BAT) on the Swift MIDEX Mission

    Get PDF
    The Burst Alert Telescope (BAT) is one of 3 instruments on the Swift MIDEX spacecraft to study gamma-ray bursts (GRBs). The BAT first detects the GRB and localizes the burst direction to an accuracy of 1-4 arcmin within 20 sec after the start of the event. The GRB trigger initiates an autonomous spacecraft slew to point the two narrow field-of-view (FOV) instruments at the burst location within 20-70 sec so to make follow-up x-ray and optical observations. The BAT is a wide-FOV, coded-aperture instrument with a CdZnTe detector plane. The detector plane is composed of 32,768 pieces of CdZnTe (4x4x2mm), and the coded-aperture mask is composed of approximately 52,000 pieces of lead (5x5x1mm) with a 1-m separation between mask and detector plane. The BAT operates over the 15-150 keV energy range with approximately 7 keV resolution, a sensitivity of approximately 10E-8 erg*cm^-2*s^-1, and a 1.4 sr (half-coded) FOV. We expect to detect >100 GRBs/yr for a 2-year mission. The BAT also performs an all-sky hard x-ray survey with a sensitivity of approximately 2 mCrab (systematic limit) and it serves as a hard x-ray transient monitor.Comment: 18 Pages, 12 Figures, To be published in Space Science Review

    Using the Wigner-Ibach Surmise to Analyze Terrace-Width Distributions: History, User's Guide, and Advances

    Full text link
    A history is given of the applications of the simple expression generalized from the surmise by Wigner and also by Ibach to extract the strength of the interaction between steps on a vicinal surface, via the terrace width distribution (TWD). A concise guide for use with experiments and a summary of some recent extensions are provided.Comment: 11 pages, 4 figures, reformatted (with revtex) version of refereed paper for special issue of Applied Physics A entitled "From Surface Science to Device Physics", in honor of the retirements of Prof. H. Ibach and Prof. H. L\"ut

    Performance of the ROX index to predict intubation in immunocompromised patients receiving high-flow nasal cannula for acute respiratory failure

    Get PDF
    Background Delayed intubation is associated with high mortality. There is a lack of objective criteria to decide the time of intubation. We assessed a recently described combined oxygenation index (ROX index) to predict intubation in immunocompromised patients. The study is a secondary analysis of randomized trials in immunocompromised patients, including all patients who received high-flow nasal cannula (HFNC). The first objective was to evaluate the accuracy of the ROX index to predict intubation for patients with acute respiratory failure. Results In the study, 302 patients received HFNC. Acute respiratory failure was mostly related to pneumonia (n = 150, 49.7%). Within 2 (1-3) days, 115 (38.1%) patients were intubated. The ICU mortality rate was 27.4% (n = 83). At 6 h, the ROX index was lower for patients who needed intubation compared with those who did not [4.79 (3.69-7.01) vs. 6.10 (4.48-8.68), p < 0.001]. The accuracy of the ROX index to predict intubation was poor [AUC = 0.623 (0.557-0.689)], with low performance using the threshold previously found (4.88). In multivariate analysis, a higher ROX index was still independently associated with a lower intubation rate (OR = 0.89 [0.82-0.96], p = 0.04). Conclusion A ROX index greater than 4.88 appears to have a poor ability to predict intubation in immunocompromised patients with acute respiratory failure, although it remains highly associated with the risk of intubation and may be useful to stratify such risk in future studies

    The Next-to-Minimal Supersymmetric Standard Model

    Full text link
    We review the theoretical and phenomenological aspects of the Next-to-Minimal Supersymmetric Standard Model: the Higgs sector including radiative corrections and the 2-loop beta-functions for all parameters of the general NMSSM; the tadpole and domain wall problems, baryogenesis; NMSSM phenomenology at colliders, B physics and dark matter; specific scenarios as the constrained NMSSM, Gauge Mediated Supersymmetry Breaking, U(1)'-extensions, CP and R-parity violation.Comment: 144 pages, 11 figures, corrections in Eqs.(2.2), (2.21), (B.9

    A 100%-complete sequence reveals unusually simple genomic features in the hot-spring red alga Cyanidioschyzon merolae

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>All previously reported eukaryotic nuclear genome sequences have been incomplete, especially in highly repeated units and chromosomal ends. Because repetitive DNA is important for many aspects of biology, complete chromosomal structures are fundamental for understanding eukaryotic cells. Our earlier, nearly complete genome sequence of the hot-spring red alga <it>Cyanidioschyzon merolae </it>revealed several unique features, including just three ribosomal DNA copies, very few introns, and a small total number of genes. However, because the exact structures of certain functionally important repeated elements remained ambiguous, that sequence was not complete. Obviously, those ambiguities needed to be resolved before the unique features of the <it>C. merolae </it>genome could be summarized, and the ambiguities could only be resolved by completing the sequence. Therefore, we aimed to complete all previous gaps and sequence all remaining chromosomal ends, and now report the first nuclear-genome sequence for any eukaryote that is 100% complete.</p> <p>Results</p> <p>Our present complete sequence consists of 16546747 nucleotides covering 100% of the 20 linear chromosomes from telomere to telomere, representing the simple and unique chromosomal structures of the eukaryotic cell. We have unambiguously established that the <it>C. merolae </it>genome contains the smallest known histone-gene cluster, a unique telomeric repeat for all chromosomal ends, and an extremely low number of transposons.</p> <p>Conclusion</p> <p>By virtue of these attributes and others that we had discovered previously, <it>C. merolae </it>appears to have the simplest nuclear genome of the non-symbiotic eukaryotes. These unusually simple genomic features in the 100% complete genome sequence of <it>C. merolae </it>are extremely useful for further studies of eukaryotic cells.</p

    A united statement of the global chiropractic research community against the pseudoscientific claim that chiropractic care boosts immunity.

    Get PDF
    BACKGROUND: In the midst of the coronavirus pandemic, the International Chiropractors Association (ICA) posted reports claiming that chiropractic care can impact the immune system. These claims clash with recommendations from the World Health Organization and World Federation of Chiropractic. We discuss the scientific validity of the claims made in these ICA reports. MAIN BODY: We reviewed the two reports posted by the ICA on their website on March 20 and March 28, 2020. We explored the method used to develop the claim that chiropractic adjustments impact the immune system and discuss the scientific merit of that claim. We provide a response to the ICA reports and explain why this claim lacks scientific credibility and is dangerous to the public. More than 150 researchers from 11 countries reviewed and endorsed our response. CONCLUSION: In their reports, the ICA provided no valid clinical scientific evidence that chiropractic care can impact the immune system. We call on regulatory authorities and professional leaders to take robust political and regulatory action against those claiming that chiropractic adjustments have a clinical impact on the immune system
    corecore